§ 5245. Blasting Operations During Lightning and Dust Storms.  


Latest version.
  • (a) Upon the approach of a lightning or dust storm, blasting operations shall be stopped and all persons in the blast area withdrawn to a safe location.
    (b) Provisions shall be made for warning crews when an electric or dust storm approaches.
    (c) In underground operations using electrical blasting systems, instrumentation to determine the presence of a lightning and dust storm within 15 miles of the portal and means to signal the heading shall be provided.
HISTORY
1. Amendment of section heading and section and new Note filed 7-11-2003; operative 8-10-2003 (Register 2003, No. 28).

Note

Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.