§ 5049. Defective Hoist or Sling Hooks and Rings.  


Latest version.
  • (a) Deformed or defective hooks or rings shall not be used.
    (b) Deformed hooks or rings shall be replaced or repaired and reshaped under proper metallurgical control and proof tested.
    (c) Annealing or normalizing shall be done only in accordance with the chain manufacturer's specifications.
    (d) Hooks and shackles shall be used in accordance with manufacturer's recommendations.
    (e) All hooks for which no applicable manufacturer's recommendations are available shall be tested to twice the intended safe working load before they are initially put into use. The employer shall maintain and keep readily available a certification record which includes the date of the test, the signature of the person who performed the test, and an identifier of the hook which was tested.
    (f) Special custom design grabs, hooks, clamps, or other lifting accessories for such units as modular panels, prefabricated structures and similar materials, shall be marked to indicate the safe working loads and shall be proof-tested to 125 percent of the rated load prior to use.
    (g) Shackles. Employers must ensure that shackles:
    (1) Have permanently affixed and legible identification markings as prescribed by the manufacturer that indicate the recommended safe working load;
    (2) Not be loaded in excess of its recommended safe working load as prescribed on the identification markings by the manufacturer; and
    (3) Not be used without affixed and legible identification markings as required by subsection (g)(1) of this section.
HISTORY
1.New subsections (d) and (e) filed 5-1-87; operative 5-31-87 (Register 87, No. 19).
2. Relettering of former subsection (e) to subsection (f), and new subsection (e) filed 3-5-90; operative 4-4-90 (Register 90, No. 12).
3. Change without regulatory effect providing proper placement for History 2 filed 4-13-2004 pursuant to section 100, title 1, California Code of Regulations (Register 2004, No. 16).
4. New subsections (g)-(g)(3) filed 1-18-2012; operative 1-18-2012 pursuant to Labor Code section 142.3(a)(4)(C). Submitted to OAL for printing only pursuant to Labor Code section 142.3(a)(3) (Register 2012, No. 3).

Note

Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.