§ 2584.4. Overhead Conductor Clearances.
Latest version.
- Amusement rides and amusement attractions shall be maintained not less than 15 feet (4.57 m) in any direction from overhead conductors operating at 600 volts or less, except for the conductors supplying the amusement ride or attraction. Amusement rides or attractions may not be located under or within 15 feet (4.57 m) horizontally of conductors operating in excess of 600 volts.HISTORY1. New section filed 5-5-2008; operative 5-5-2008. Submitted to OAL for printing only pursuant to Labor Code 142.3(a)(3) (Register 2008, No. 19).