California Code of Regulations (Last Updated: August 6, 2014) |
Title 8. Industrial Relations |
Division 1. Department of Industrial Relations |
Chapter 4. Division of Industrial Safety |
Subchapter 14. Petroleum Safety Orders -Drilling and Production |
Article 18. Standard Type Derricks |
§ 6563. Derrick Gin Pole.
Latest version.
- (a) A derrick gin pole or other equivalent means shall be provided on every derrick tower when it is necessary to raise or lower a crown block to or from the top of the derrick tower.(b) A derrick gin pole shall not be subjected to loads greater than the design and condition of the structure will withstand.(c) Every derrick gin pole used to handle a crown block shall have sufficient height above the derrick crown (water table) to permit the crown block to be raised to a point at least two feet (2 ') in the clear above the top of the water table.(d) When a derrick gin pole is used to install a crown block, access shall be provided to the top of the derrick gin pole by means of a fixed ladder.HISTORY1. Amendment of subsection (b) and new Note filed 5-8-95; operative 6-7-95 (Register 95, No. 19).
Note
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.