§ 64673. Small and Medium-Size Water System Requirements.  


Latest version.
  • (a) The requirements in this section are applicable to all small and medium-size water systems.
    (b) Each small and medium-size system shall conduct standard tap sampling for lead and copper pursuant to section 64675 (General Requirements for Tap Sampling for Lead and Copper). Tap sampling frequency may be reduced pursuant to section 64675.5 (Tap Sampling Frequency).
    (c) A small or medium-size system with an action level exceedance shall take the following steps:
    (1) Monitor WQPs beginning with the first period after the exceedance, pursuant to section 64681 (Initial WQP Monitoring).
    (2) Proceed with subparagraphs (A) through (E) if a corrosion control study is required by the Department based on a review of the system's water quality, distribution system, water treatment, and system features. If such a study is required, the Department will notify the system in writing within 12 months of the action level exceedance.
    (A) Complete the study, pursuant to section 64683 (Corrosion Control Study Procedure), within eighteen months of being notified of the requirement; the system will be notified of the Department's designation within six months of the study's completion;
    (B) Begin installation of the CCT designated by the Department, pursuant to section 64684 (CCT Installation and Operation), within twelve months of being notified of the Department's designation;
    (C) Complete CCT installation and begin operation within 24 months of the designation;
    (D) Complete two periods of standard tap sampling pursuant to section 64675 (General Requirements for Tap Sampling for Lead and Copper) and two periods of WQP monitoring pursuant to section 64682 (WQP Monitoring After CCT Installation) within 36 months of the designation; and
    (E) Monitor WQPs and operate in compliance with the WQP levels specified by the Department pursuant to section 64684 (CCT Installation and Operation), beginning no later than within 42 months of the designation.
    (3) If the Department does not require a corrosion control study, the system shall submit to the Department, within six months of the action level exceedance, a written recommendation for CCT. The Department may require the system to conduct additional WQP monitoring to assist in the review of the CCT recommendation. The Department will designate CCT and notify the system in writing within the following timeframes; the system shall then comply with paragraphs (2)(B) through (E):
    (A) For medium-size systems, within 12 months of the exceedance, and
    (B) For small-size systems, within 18 months of the exceedance;
    (4) Monitor source waters, pursuant to article 6 (Source Water Requirements for Action Level Exceedances) of this chapter;
    (d) A small or medium-size system with an action level exceedance for lead shall:
    (1) Complete a lead public education program, pursuant to article 7 (Public Education Program for Lead Action Level Exceedances) of this chapter; and
    (2) Replace lead service lines, pursuant to article 8 (Lead Service Line Requirements for Action Level Exceedances) of this chapter.
    (e) A small or medium-size system that is required to comply with subsections (c) or (d) may cease completing the steps whenever the system does not have an action level exceedance during each of two consecutive periods. If any such system thereafter has an exceedance during any period, the system shall:
    (1) Resume completion of the applicable steps, beginning with the first step that was not previously completed. The Department may require a system to repeat steps previously completed if the Department determines that this is necessary to implement the requirements of this section, based on a review of the system's data and treatment status.
    (2) Resume standard tap sampling pursuant to 64675 (General Requirements for Tap Sampling for Lead and Copper).
    (3) Conduct WQP monitoring during the period in which the system exceeded the action level, pursuant to section 64682, (WQP Monitoring After CCT Installation) or 64684 (CCT Installation and Operation).
HISTORY
1. New article 2 and section filed 12-11-95 as an emergency; operative 12-11-95 (Register 95, No. 50). A Certificate of Compliance must be transmitted to OAL by 4-9-96 or emergency language will be repealed by operation of law on the following day.
2. Refiling of 12-11-95 order, including amendment of Note, filed 4-9-96 as an emergency; operative 4-10-96 (Register 96, No. 15). A Certificate of Compliance must be transmitted to OAL by 8-8-96 or emergency language will be repealed by operation of law on the following day.
3. Editorial correction of subsection (b)(2)(B) (Register 96, No. 38).
4. Certificate of Compliance as to 12-11-95 order transmitted to OAL 8-7-96 and filed 9-16-96 (Register 96, No. 38).
5. Repealer of article 2 (sections 64673-64676), new article 2 (sections 64673-64674) and repealer and new section filed 9-11-2003; operative 10-11-2003 (Register 2003, No. 37).

Note

Note: Authority cited: Sections 100275, 116350, 116365 and 116375, Health and Safety Code. Reference: Sections 116325-116750, Health and Safety Code.