California Code of Regulations (Last Updated: August 6, 2014) |
Title 13. Motor Vehicles |
Division 2. Department of the California Highway Patrol |
Chapter 2. Lighting Equipment |
Article 11. Deceleration Signal Lamp Systems |
§ 734. Temperature Test Requirements.
Latest version.
- The control system shall meet the following requirements at both 11 V and 15 V:(a) Low Temperature Test. The control system shall be placed in its normal operating position in a circulating air cabinet at -32 ± 3 degrees C (-25 ±5 degrees F) for 2 h. At the end of that period and while still at that temperature, the unit shall meet the requirements in Table I at 0 g and 0.3 g.(b) High Temperature Test. The control system shall be placed in its normal operating position in a circulating air cabinet at 74 + 0, -2.8 degrees C (165 + 0, -5 degrees F) for 2 h. At the end of that period and while still at that temperature, the unit shall meet the requirements in Table I at 0 g and 0.3 g.
Note
Note: Authority cited: Section 26103, Vehicle Code. Reference: Sections 24012 and 26103, Vehicle Code.